@TCWORLD TCWORLD commented Nov 15, 2025

The new clamping of PV limit in Mode 8 Export First mode requires further investigation. This is causing a ramp down oscillation of PV output due to the hysteresis setting.

As this is new logic not originally in this pathway, I'm proposing we make the section of code default to disabled until it has undergone further testing and development.

See #1730 for tracking of this.

The new clamping of PV limit in Mode 8 Export First mode requires further investigation. This is causing a ramp down oscillation of PV output due to the hysteresis setting.

While under development, make the section of code default to disabled.

See wills106#1730 for tracking of this.
When disabled, the log message can't find one of its arguments. Set it to the full pv limit.